Simulation and LCC assessment

The results of the case simulations can be summarised as follows:
Annual final operation energy use (kWh/m2) before and after implementation of different energy measures. Each successive measure includes the effects of all previous measures.

Description Space
heating
Tap water
heating
Ventilation
electricity
Total
Initial 102 25 4 130
Intermediate scenario
+ Improved taps 102 102 15  4  120
+ Attic floor insulation  87  15  4  105
+ Improved windows and doors  51  15  4  70
+ External walls insulation  44  15  4  63
+ Ventilation heat recovery  23  15  7  45
Sustainability scenario
+ Improved taps  41  15  4 60
+ Attic floor insulation  102  15  4  120
+ Improved windows and doors  86  15  4  104
+ External walls insulation  48  15  4  67
+ Ventilation heat recovery  20  15  7  42

The results of the LCCost analysis of energy renovation measures for apartment buildings can
be seen from the slides in the attached appendix.

Want to know more?

Delivery no. D.2.1.1 Simulation and LCC assessment – decision note on design options
Please contact: Mr. Ambrose Doodoo, Linnaeus Universitet, ambrose.dodoo@lnu.se